Log in
Propaedeutics · Cardiovascular system

Electrical axis of the heart

The electrical axis of the heart (EAH) is the resultant vector of electrical forces that occupies a specific position in the frontal plane. The maximum electrical activity of the myocardium is recorded during ventricular excitation and is reflected on the electrocardiogram as the QRS complex.

Alpha angleFormed by the EAH vector and the horizontal line of lead I
NormogramNormal axis position ranges from +30° to +70°
R waveNormally, its maximum amplitude is observed in lead II
Causes of shiftsThe axis shifts under the influence of the patient's body habitus and myocardial pathologies
4 min readFor medical studentsUpdated 09/24/2026
Material prepared by WhiteCoat Pro editorial team based on platform study guidesReviewed by medical editor: Aulov A. A., general practitioner · 09/24/2026

Alpha angle and methods for determining the EAH

The direction of the electrical axis is assessed using the alpha ($\alpha$) angle. It is formed by the total depolarization vector and the horizontal zero line, which corresponds to standard lead I.

If the vector is directed below this horizontal line, the angle is considered positive, and if it goes above, it is negative.

In clinical practice, two methods are used to determine the axis position:

  1. Visual (approximate) — the physician quickly estimates the position of the vector by comparing the height and depth of the QRS complex waves in various standard leads.
  2. Geometric (calculated) — a more precise method that requires plotting the vector within Einthoven's triangle based on the amplitude of the QRS waves in two leads.

Classification of EAH positions

Depending on the degree value of the $\alpha$ angle, five main positions of the resultant vector are distinguished:

  • Left axis deviation (levogram): from 0° to -90°.
  • Horizontal position: from 0° to +30° (an intermediate variant between normal and left axis deviation).
  • Normal position (normogram): approximately from +30° to +70°.
  • Vertical position: from +70° to +90° (an intermediate variant between normal and right axis deviation).
  • Right axis deviation (dextrogram): from +90° to +180°.
Test your knowledgeTasks from the "Propaedeutics" course bank — get answers and explanations instantly.

Visual assessment using standard leads

The basic method for rapid electrical axis (EA) analysis involves evaluating leads I and III. Anatomical landmarks (right arm, left arm, left leg) form Einthoven's triangle. The direction of the vector relative to these sides determines the shape of the QRS complex.

  • In norm, the vector is directed to the left and downwards (along lead II). The R wave predominates in all standard leads.
  • With right axis deviation, the vector points toward the right half of the body. Lead I shows a deep negative S wave, while lead III is dominated by a tall R wave.
  • With left axis deviation, the vector points sharply to the left and upwards. Lead I records a tall R wave, while lead III is dominated by a deep S wave.

Detailed ECG features of various positions

Normogram In all three standard leads, the R wave is larger than the S wave. The tallest R wave is recorded in the II standard lead. In augmented leads (aVL and aVF), R also predominates, with aVF typically showing a higher R wave.

Dextrogram Maximum R amplitude is observed in lead III. It is characterized by a progressive decrease in wave height from lead III to lead I ($R_{III} > R_{II} > R_{I}$). In aVF, the R wave is tall, whereas in aVL, the S wave is deep.

Levogram The R wave is most prominent in lead I ($R_{I} > R_{II} > R_{III}$). In lead III, the complex is predominantly negative (r may be completely absent). In lead aVL, the R wave is tall and almost equals that in lead I.

Intermediate positions With a vertical axis, the complex in lead I has a low voltage, but $R > S$ is strictly maintained (a key difference from a dextrogram). The R amplitudes in leads II and III are approximately equal. With a horizontal axis, the R amplitudes in leads I and II are practically equal. In lead III, the S wave exceeds the small r wave, although upon inspiration, the r amplitude in this lead increases.

Briefly: answers to topical questions

What specific pathological conditions lead to left electrical axis deviation of the heart?

Pathological conditions explicitly stated in the sources include left ventricular hypertrophy.

  • Left ventricular hypertrophy causes leftward EA deviation: as a general rule, the EA deviates toward the hypertrophied ventricle.
  • For this sign, the source specifies a condition: the absence of left anterior fascicular block; it is also noted that the sign has low specificity.

What diseases and syndromes cause right electrical axis deviation of the heart?

Conditions explicitly stated in the sources as associated with right EA deviation include:

  • Right ventricular hypertrophy — the EA deviates toward the hypertrophied ventricle; for the axis to shift to the right, right ventricular hypertrophy must be significant, since its normal mass is 6 times less than that of the left ventricle.
  • Chronic cor pulmonale — the diagnostic table lists right EA deviation and right ventricular hypertrophy for this condition.
How to memorize

Quick visual assessment method: look at the QRS complexes in leads I and III. If the waves "face" each other (lead I points down, lead III points up) — this is right axis deviation. If the waves "diverge" in opposite directions (lead I points up, lead III points down) — this is left axis deviation.

Class and exam questions

What does a horizontal axis position mean?

This is an intermediate variant between the normogram and left axis deviation. The alpha angle in this case ranges from 0° to +30°.

What is the difference between a vertical axis position and pronounced right axis deviation?

With a vertical axis, the amplitude of the complex in lead I is small, but the R wave is still larger than the S wave. In a dextrogram, the S wave dominates in lead I.

What determines changes in EA position?

The shift in the net electrical vector is caused by both constitutional (extracardiac) body type factors and various pathological causes.

Something unclear? Ask the AIThe AI tutor has read the material on "Electrical axis of the heart" and will explain it in simple terms.

What else to study on this topic

  • Algorithm for the geometric calculation of the alpha angle in Einthoven's triangle
  • Functional respiratory tests in assessing horizontal axis position
  • Morphology of aVL and aVF complexes during EA shifts
  • Relationship between vector direction and anatomical limb landmarks
  • Causes leading to pronounced left and right axis deviation

Master the entire topic in the "Propaedeutics" course

This is a summary. The course covers everything tested in classes and exams.

  • Complete study guide on "Electrical axis of the heart" and 3,152 other pages of the subject
  • Assignments and quizzes after every topic — just like in a colloquium
  • AI tutor answers questions on the topic anytime
  • 113 video lessons on the subject

Other topics in the "Cardiovascular system" section

The entire "Cardiovascular system" section

Prepared by WhiteCoat Pro faculty in accordance with the medical school curriculum. For educational purposes only.